AKSA Silent Towable Diesel Generator -APD-AT56 - 51-56 kW 3 Phase, 45-50 kW 1-Phase, Skid or Towable
SKU: APD-AT56
Model: APD-AT56
Status: Discontinued
This Product Has Been Discontinued.
We Recommend the Following:
Click Here to View Related Product(s)
Documentation
Brochure/Specification | |
Warranty Terms & Conditions | |
Warranty Terms & Conditions (Engine) |
Fuel
Diesel
Grade
Commercial, Emergency, Industrial, Professional
Style
Emergency Standby Generator, Portable Generator, Towable Generator
Starting
Electric
Watts (Rated)
51,000
Watts (Surge)
56,000
Engine
Compliance
49 State Compliant
Product
Manufacturer | inactive |
---|---|
SKU | APD-AT56 |
Model Number | APD-AT56 |
Generator Grade | Commercial, Emergency, Industrial, Professional |
Generator Style | Emergency Standby Generator, Portable Generator, Towable Generator |
Special Features | 1800 RPM, 50 Amp Plug, Brushless Alternator, Fuel Gauge, GFCI Protection - Partial, Hour Meter, Liquid Cooled, Voltmeter, Wheel Kit |
Engine Details
Engine/Motor Brand | Perkins |
---|---|
Engine Model | 1104D-44TG1 |
Fuel Type | Diesel |
Starting System | Electric |
Horsepower | 85.8 HP |
Engine/Motor Type | 4-Cylinder, Water-Cooled, 4-Stroke, Direct Injected, Turbo-Charged, In-Line |
Displacement | 4400 cc |
Engine RPM | 1800 RPM |
Generator RPM | 1800 RPM |
Fuel Capacity | 178.00 Gallons |
Run Time @ 50% Ld (Hrs) | 74.8 |
Run Time @ 75% Ld (Hrs) | 52.4 |
Run Time @ 100% Ld (Hrs) | 40.5 |
Fuel Cons. @ 50% Ld | 2.38 Gallons/Hour |
Fuel Cons. @ 100% Ld | 4.39 Gallons/Hour |
Fuel Gauge | Included |
Enclosure | Sound-Attenuating |
Low Oil Shutdown/Alert | Yes |
Engine Governor | Electronic |
Operational Volume (dB @23ft) | 73.0 |
Overload Protection | Yes |
Altitude Affected | Yes, Call For More Information |
Generator Details
Surge Start Watts | 56,000.0 |
---|---|
Continuous Rated Watts | 51,000.0 |
Prime Rating Watts | 51,000 |
Phase | Single-Phase, 3-Phase, Simultaneous 1 & 3 Phase (Limited) |
Voltage | 120, 240 1-Phase, 120, 208, 277, 480 3-Phase, Switchable |
Rated Amps @ Max Volt (Commonly 240v 1-Phase) | 187.0 |
Rated Amps @ 208 Volts (3-Phase) | 177.0 |
Rated Amps @ 480 Volts (3-Phase) | 77.0 |
Leads | 12 |
GFCI Panel Protection | Partial |
Frequency | 60 Hz |
Poles | 4 |
Alternator | Brushless |
Voltage Regulation | Auto Voltage Regulation |
Frequency Regulation | E-Governing Control |
Circuit Breakers | 200 Amp |
Control Panel Display | Voltmeter, Voltage Selector Switch, Ammeter, Frequency Meter, Hour Meter, Engine Speed, Battery Voltage, Oil Pressure Gauge, Water Temperature Gauge, LCD, Ammeter Phase Selector Switch, Voltmeter Phase Selector Switch, Voltage Regulator Adjustment Potentiometer, Automatic Safety Shutdown System Monitors: Water Temp, Engine Oil Pressure, Low Coolant, Overspeed, and Overcrank. Warning Lights Indicate Abnormal Conditions., Warning Lights (oil, water) |
Outlets
NEMA 5-20R Duplex (GFCI) (20 Amp 120, 2 Each)
CS6369 (50 Amp 120/240, 3 Each)
Camlocks
|
Accessories
Portability/Wheel Kit | Add @ Checkout |
---|---|
Vibration Isolators | Yes |
Lifting Hook/Eye | Included (On Trailer) |
Jacket Water Heater | Included |
Trickle Battery Charger | Included |
Start Up Oil | Included |
Battery For Electric Start | Included |
Volts | 12 |
Warranty
Prime Power Warranty | 1 Year Or 2000 Hours |
---|---|
Standby Warranty | 2 Years Or 2000 Hours |
Other Information
Weight (Lbs.) | 3516 |
---|---|
Ship Weight (Lbs.) | 3516 |
Dimension No Wheel Kit | 122.0"L x 42.0"W x 75.0"H |
Dimension W/Wheel Kit | 175.0"L x 66.0"W x 89.0"H |
Agency Compliance | EPA Tier 3 FLEX |
California Destination-Operators-Buyers Warning | Click Here For California Proposition 65 Warning |
Stk. Itm. | No |
AKSA Silent Towable Diesel Generator - 51-56 kW 3 Phase, 45-50 kW 1-Phase, Skid or Towable
- Heavy duty Perkins 1104D-44TG1, 85.8 HP, diesel engine - EPA Tier-3 FLEX
- 60 Hz, 1800 rpm
- 56 kW stand-by output power in 480V & 208V 3phase, 50 kW standby in 240V single phase
- 3 position VSS, 480V & 208V 3-phase, 240V single phase
- Sound attenuated enclosure with extra-large doors for serviceability
- Stamford UC1224F125◦C alternator
- 178 gallon single walled fuel tank
- Residential grade exhaust silencer and steel bellows
- DSE7320 model controller
- Simultaneous single and three phase power. The single phase power is always available via the 120 volt GFCI duplex receptacles
- Battery, battery charger, battery cables included
- Hot-start 1000W Jacket Water Heater
- Three 50 amp California Style locking receptacles
- Two 20 amp GFCI receptacles
- Five 400A rated stud type quick connect cam-locks
- Two wire start connection for emergency backup application
- Shore power for battery charger and jacket water heater
- Optional DOT approved 7k LB Tandem (dual) axle trailer, with electric brakes & lights, 2 5/16 Inch Ball Hitch (Add @ Checkout)
- Rear Stabilizer Jacks, Storage Box and Spare Tire
- Fluids included
The AKSA ADP-AT56 is a great value for an Industrial grade generator with 51,000 watts of prime power, metal sound attenuated enclosure, robust control panel, and a DOT approved trailer for portability. With a run time of 40.5 hours at 100% load on one tank of diesel fuel, this generator is ideal for municipalities, emergency recovery, construction sites, and special events. Backed by a 2 year or 2000 hour standby and 1 year or 2000 hour prime warranty, this portable generator is truly a great value.
- Shipments < 150 lbs. Will Be By FedEx Or UPS To Garage Or Front Door
- Shipments > 150 lbs. Will Be By Extes-Express, RL Carriers, Or Other To Curbside At Truck Deck Height
- Standard Freight To Lower 48 States
- Standard Freight Does Not Include Service To Alaska, Hawaii, Or Destinations Outside The United States. Contact Us To Make Other Accommodations For Shipments Outside The Lower 48 States.